dell服务器安装PERCCLI

2023-12-08 07:28
文章标签 安装 服务器 dell perccli

本文主要是介绍dell服务器安装PERCCLI,希望对大家解决编程问题提供一定的参考价值,需要的开发者们随着小编来一起学习吧!

因在linux 系统中无法查看系统磁盘的raid级别,也无法得知raid状态,需要安装额外的包来监控,因是dell服务器,就在dell网站中下载并安装

1、下载链接:驱动程序和下载 | Dell 中国icon-default.png?t=N7T8https://www.dell.com/support/home/zh-cn?app=drivers选择产品型号并选择驱动类型

下载的包如下图,下载后上传到/opt目录下

在主机安装并使用

root@hydb opt]# rpm -ivh perccli-1.17.10-1.noarch.rpm
Verifying...                          ################################# [100%]
Preparing...                          ################################# [100%]
Updating / installing...
   1:perccli-1.17.10-1                ################################# [100%]
[root@hydb opt]#

[root@hydb perccli]# ln -s /opt/MegaRAID/perccli/perccli64 /bin/perccli
[root@hydb ~]#

[root@hydb ~]#  perccli /c0/eall/sall show
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
[root@hydb ~]# perccli /c0/vall show
Controller = 0
Status = Success
Description = None


Virtual Drives :
==============

-----------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
-----------------------------------------------------------------------
1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
-----------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
[root@hydb ~]# perccli show ctrlcount
Status Code = 0
Status = Success
Description = None

Controller Count = 1

查看控制器的信息

**perccli show ctrlcount 查看有几个控制器即几个raid卡 **

perccli show 显示raid卡信息
[root@hydb ~]# perccli show
Status Code = 0
Status = Success
Description = None

Number of Controllers = 1
Host Name = dbdg
Operating System  = Linux5.15.0-101.103.2.1.el8uek.x86_64

System Overview :
===============

---------------------------------------------------------------------------
Ctl Model           Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
---------------------------------------------------------------------------
  0 PERCH750Adapter     8   5   2     0   2     0 Opt On  -  N      0 Opt  
---------------------------------------------------------------------------

Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit
Hlth=Health|Safe=Safe-mode boot
[root@hydb ~]# perccli /c0 show
Generating detailed summary of the adapter, it may take a while to complete.

Controller = 0
Status = Success
Description = None

Vendor Id = 0x1000
Device Id = 0x10E2
SubVendor Id = 0x1028
SubDevice Id = 0x2176
Host Interface = PCI-E
Device Interface = SATA-3G
Bus Number = 134
Device Number = 0
Function Number = 0
Drive Groups = 2

TOPOLOGY :
========

--------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace
--------------------------------------------------------------------------
 0 -   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
 0 0   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
 0 0   0   64:0     2   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
 0 0   1   64:1     0   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
 1 -   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
 1 0   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
 1 0   0   64:2     1   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
 1 0   1   64:3     4   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
--------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present

Virtual Drives = 2

VD LIST :
=======

-----------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
-----------------------------------------------------------------------
0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
-----------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 5

PD LIST :
=======

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


BBU_Info :
========

-------------------------------------------------------------------
Model State   RetentionTime Temp Mode MfgDate Next Learn           
-------------------------------------------------------------------
BBU   Optimal 0 hour(s)     31C  -    0/00/00 2024/02/20  03:22:19
-------------------------------------------------------------------
[root@hydb ~]#
看磁盘的Device id、Slot No. 以及DriveGroup
[root@hydb ~]#  perccli /c0/eall/sall show
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.

Drive Information :
=================

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


[root@hydb ~]#
[root@hydb ~]# lsscsi
[0:3:110:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sda
[0:3:111:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sdb
[root@hydb ~]#

这篇关于dell服务器安装PERCCLI的文章就介绍到这儿,希望我们推荐的文章对编程师们有所帮助!



http://www.chinasem.cn/article/469022

相关文章

springboot上传zip包并解压至服务器nginx目录方式

《springboot上传zip包并解压至服务器nginx目录方式》:本文主要介绍springboot上传zip包并解压至服务器nginx目录方式,具有很好的参考价值,希望对大家有所帮助,如有错误... 目录springboot上传zip包并解压至服务器nginx目录1.首先需要引入zip相关jar包2.然

将Java项目提交到云服务器的流程步骤

《将Java项目提交到云服务器的流程步骤》所谓将项目提交到云服务器即将你的项目打成一个jar包然后提交到云服务器即可,因此我们需要准备服务器环境为:Linux+JDK+MariDB(MySQL)+Gi... 目录1. 安装 jdk1.1 查看 jdk 版本1.2 下载 jdk2. 安装 mariadb(my

如何在Mac上安装并配置JDK环境变量详细步骤

《如何在Mac上安装并配置JDK环境变量详细步骤》:本文主要介绍如何在Mac上安装并配置JDK环境变量详细步骤,包括下载JDK、安装JDK、配置环境变量、验证JDK配置以及可选地设置PowerSh... 目录步骤 1:下载JDK步骤 2:安装JDK步骤 3:配置环境变量1. 编辑~/.zshrc(对于zsh

如何在pycharm安装torch包

《如何在pycharm安装torch包》:本文主要介绍如何在pycharm安装torch包方式,具有很好的参考价值,希望对大家有所帮助,如有错误或未考虑完全的地方,望不吝赐教... 目录在pycharm安装torch包适http://www.chinasem.cn配于我电脑的指令为适用的torch包为总结在p

在PyCharm中安装PyTorch、torchvision和OpenCV详解

《在PyCharm中安装PyTorch、torchvision和OpenCV详解》:本文主要介绍在PyCharm中安装PyTorch、torchvision和OpenCV方式,具有很好的参考价值,... 目录PyCharm安装PyTorch、torchvision和OpenCV安装python安装PyTor

Python Transformer 库安装配置及使用方法

《PythonTransformer库安装配置及使用方法》HuggingFaceTransformers是自然语言处理(NLP)领域最流行的开源库之一,支持基于Transformer架构的预训练模... 目录python 中的 Transformer 库及使用方法一、库的概述二、安装与配置三、基础使用:Pi

如何解决mmcv无法安装或安装之后报错问题

《如何解决mmcv无法安装或安装之后报错问题》:本文主要介绍如何解决mmcv无法安装或安装之后报错问题,具有很好的参考价值,希望对大家有所帮助,如有错误或未考虑完全的地方,望不吝赐教... 目录mmcv无法安装或安装之后报错问题1.当我们运行YOwww.chinasem.cnLO时遇到2.找到下图所示这里3.

Python 安装和配置flask, flask_cors的图文教程

《Python安装和配置flask,flask_cors的图文教程》:本文主要介绍Python安装和配置flask,flask_cors的图文教程,本文通过图文并茂的形式给大家介绍的非常详细,... 目录一.python安装:二,配置环境变量,三:检查Python安装和环境变量,四:安装flask和flas

基于Python打造一个可视化FTP服务器

《基于Python打造一个可视化FTP服务器》在日常办公和团队协作中,文件共享是一个不可或缺的需求,所以本文将使用Python+Tkinter+pyftpdlib开发一款可视化FTP服务器,有需要的小... 目录1. 概述2. 功能介绍3. 如何使用4. 代码解析5. 运行效果6.相关源码7. 总结与展望1

使用Python开发一个简单的本地图片服务器

《使用Python开发一个简单的本地图片服务器》本文介绍了如何结合wxPython构建的图形用户界面GUI和Python内建的Web服务器功能,在本地网络中搭建一个私人的,即开即用的网页相册,文中的示... 目录项目目标核心技术栈代码深度解析完整代码工作流程主要功能与优势潜在改进与思考运行结果总结你是否曾经